Change Language
Call Us08045479132
DIGITAL COLONY COUNTER- RS-361, 62, 63

DIGITAL COLONY COUNTER- RS-361, 62, 63

1000.0 INR/Number

Product Details:

  • Temperature Range Ambient
  • Frequency 50 Hz
  • Measurement Range 0-999 Colonies
  • Automation Grade Semi-Automatic
  • Capacity Up to 999 colonies
  • Core Components Counting Probe, Illuminated Magnifier, Digital Display Unit
  • Power Source AC Mains
  • Click to view more
X

DIGITAL COLONY COUNTER- RS-361, 62, 63 Price And Quantity

  • 1 Number
  • 1000.0 INR/Number

DIGITAL COLONY COUNTER- RS-361, 62, 63 Product Specifications

  • 230V AC
  • Digital Colony Counter
  • RS-361, RS-362, RS-363
  • 1 Count
  • 265 x 225 x 175 mm
  • Wolffhuegel Glass Grid Marked Plate, Adjustable Light Intensity, Reset Button, Buzzer Tool for Audible Signal
  • 4-Digit LED Digital Display
  • Microbial Colony Counting in Laboratories
  • 0-999 Colonies
  • Mild Steel Body with Powder Coating, Transparent Acrylic Hood
  • Ambient
  • 50 Hz
  • AC Mains
  • Counting Probe, Illuminated Magnifier, Digital Display Unit
  • Up to 999 colonies
  • Approx 3 kg
  • Semi-Automatic
  • Powder Coated Sheet Metal
  • Microbiology, Pathology, Research Laboratories
  • Electronic Impulse via Probe
  • Manual with Probe Touch
  • 2x Magnifying Glass with Adjustable Arm
  • Standard Petri Dish (90 mm/100 mm)
  • Shadow-free LED ring light
  • Marker Pen Provided
  • Audible Buzzer on Each Count

DIGITAL COLONY COUNTER- RS-361, 62, 63 Trade Information

  • 1 Week

Product Description

The most time consuming part of carrying out a microbial count is the actual counting process on petri-dishes. Digital Colony Counter is designed for quick and accurate counting of bacterial and mould colonies in petri dishes. Feature packed and easy to use, this is an indispensable bench top tool for the busy microbiologist.
It is designed for rapid and accurate counting of bacterial and mould colonies. Simply place the petri dish on the illuminated pad and touch the dish with the pen provided to mark each colony in turn. This causes a count to be registered on the digital display and an audible tone confirms each count made. Marking the dish with the pen avoids missing colonies or double counting. The digital count on the display can be reset manually any time by pressing reset key provided.


Precise Counting Mechanism

Equipped with an electronic impulse probe and a manual touch operation, the RS-361, RS-362, and RS-363 models ensure each colony is counted accurately. The audible buzzer provides feedback for each count, reducing manual errors and enhancing consistency in results. The 4-digit LED display instantly shows the tally, making the process simple and reliable.


Enhanced Visibility and Usability

Designed for user convenience, these counters feature a shadow-free LED ring light with adjustable intensity and a 2x magnifying glass on an adjustable arm. This combination enables clear observation and effortless marking of individual colonies, even in varying lighting conditions or with faint bacterial growth.

FAQ's of DIGITAL COLONY COUNTER- RS-361, 62, 63:


Q: How does the digital colony counter work for counting colonies?

A: The digital colony counter uses an electronic impulse probe; when you touch the probe to a colony on a petri dish placed on the Wolffhuegel glass grid, it registers a count, displays it on the digital screen, and sounds an audible buzzer to confirm the action.

Q: What types of laboratories can benefit from using the RS-361, RS-362, and RS-363 colony counters?

A: These models are ideal for microbiology, pathology, and research laboratories where accurate microbial colony counting on petri dishes is essential for sample analysis and quality control.

Q: When should you use the marking facility during colony counting?

A: You should use the provided marker pen to mark each counted colony immediately after touching the probe. This prevents double-counting and ensures systematic, efficient enumeration, especially when dealing with numerous or closely clustered colonies.

Q: Where can the colony counter be set up for optimal use?

A: The colony counter should be placed on a stable laboratory workbench within an ambient temperature environment, near a 230V AC power source, to ensure smooth operation of the LED illumination and digital display.

Q: What is the process for counting colonies with this device?

A: Place your prepared petri dish on the marked plate, adjust the magnifying glass and light intensity for clear viewing, touch the electronic probe to each colony (marking as you go), and let the device automatically tally and audibly signal each count.

Q: How does this model ensure accuracy and reliability in results?

A: The combination of a manual probe, audible signal, clear magnification, and digital LED display provides a high level of count accuracy-with a precision of up to 1 count and a capacity of up to 999 colonies-minimizing user errors and enhancing repeatability.

Q: What benefits does the Wolffhuegel glass grid plate offer for microbial counting?

A: The Wolffhuegel glass grid plate provides a marked reference for standard petri dish sizes (90mm/100mm), helping users systematically scan and count colonies in defined sectors, speeding up the process and ensuring comprehensive coverage.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Lab items' category



Back to top